PartsTable TECHNICAL DATA SHEET
NSN 5925-01-078-6448Government record, cited

Circuit Breaker5925-01-078-6448

NSN 5925-01-078-6448 · NIIN 010786448 · Part number TLPN50330
L3harris Technologies Integrated Systems L.p. Dba L3harris Technologies · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 05395
Government record, cited
NSN 5925-01-078-6448 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-078-6448. Manufacturer of record part number: TLPN50330.
Also searched as  5925-01-078-6448 · 5925010786448 · NIIN 010786448 · 01-078-6448 · FSC 5925 Circuit Breakers · CAGE 05395 · TLPN50330 · AM4-C3C3A3A3-15-15-10-10-P
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 8 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 400.0 FIRST LOCATION
  • Frequency in Hertz: 400.0 SECOND LOCATION
Identification
  • NSN: 5925-01-078-6448
  • NIIN: 010786448
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: TLPN50330
  • Manufacturer: L3harris Technologies Integrated Systems L.p. Dba L3harris Technologies
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-078-6448, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is L3harris Technologies Integrated Systems L.p. Dba L3harris Technologies. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-078-6448
Primary Part NumberTLPN50330
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerL3harris Technologies Integrated Systems L.p. Dba L3harris Technologies
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity8 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Frequency in Hertz400.0 FIRST LOCATION
Frequency in Hertz400.0 SECOND LOCATION
Frequency in Hertz50.0 OR 60.0 FOURTH LOCATION
Frequency in Hertz50.0 OR 60.0 THIRD LOCATION
Unpackaged Unit Weight1.200 POUNDS NOMINAL LBS
Center to Center Distance Between Terminals Parallel to Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 THIRD LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 FOURTH LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 FIRST LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 SECOND LOCATION
External Actuator Linkage ArrangementONE, TWO, THREE, AND FOUR LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity4
Mounting Surface to Terminal End Distance2.331 INCHES MINIMUM AND 2.492 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC FIRST LOCATION
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC FOURTH LOCATION
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC THIRD LOCATION
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC SECOND LOCATION
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
TLPN50330 L3harris Technologies Integrated Systems L.p. Dba L3harris Technologies (USA)
Reference documents
ReferenceMeaning
AM4-C3C3A3A3-15-15-10-10-P 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-078-6448?

NSN 5925-01-078-6448 is a Circuit Breaker, manufactured by L3harris Technologies Integrated Systems L.p. Dba L3harris Technologies, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-078-6448?

NSN 5925-01-078-6448 has 1 manufacturer part number on file: TLPN50330 (L3harris Technologies Integrated Systems L.p. Dba L3harris Technologies).

What are the specifications of TLPN50330?

Key specifications for TLPN50330: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 8 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-078-6448 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com