The Circuit Breaker, cataloged under National Stock Number 5925-01-075-8932, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Te Connectivity Corporation. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-075-8932 |
| Primary Part Number | W67X2Q1-2-30 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Te Connectivity Corporation |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 60.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 2.500 OUNCES NOMINAL OZ |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.629 INCHES MINIMUM AND 1.691 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.812 INCHES MINIMUM AND 1.874 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 QUICK DISCONNECT, MALE |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| W67X2Q1-2-30 | Te Connectivity Corporation (USA) |
| Reference | Meaning |
|---|---|
| 5007122-03 | C/1 Advisory reference — outside the item-of-supply concept Raytheon Technical Services Company |
| JA1S-A3-A-30-2 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
| 511-230-101 | 5/9 Secondary reference Te Connectivity Corporation |
| 264-200009-001 | 5/9 Secondary reference Compro Computer Services, Inc. Dba Compro |
| JA1-A3-A-30-2 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-075-8932 is a Circuit Breaker, manufactured by Te Connectivity Corporation, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-075-8932 has 1 manufacturer part number on file: W67X2Q1-2-30 (Te Connectivity Corporation).
1 possible match (shared part number, not a government interchangeability claim): 5925-01-284-3373. Verify interchangeability with system specifications before substitution.
Key specifications for W67X2Q1-2-30: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.