The Circuit Breaker, cataloged under National Stock Number 5925-01-074-3043, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-074-3043 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SHUNT TRIP FIRST LOCATION |
| Internal Trip Release Configuration | SHUNT TRIP SECOND LOCATION |
| Internal Trip Release Configuration | SERIES TRIP FOURTH LOCATION |
| Internal Trip Release Configuration | SHUNT TRIP THIRD LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC THIRD LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 24.0 DC FOURTH LOCATION |
| Mounting Facility Type and Quantity | 8 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60.0 THIRD LOCATION |
| Frequency in Hertz | 60.0 FIRST LOCATION |
| Frequency in Hertz | 60.0 SECOND LOCATION |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 FIRST LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SECOND LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 THIRD LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 150.0 FOURTH LOCATION |
| External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.060 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT FIRST LOCATION |
| Circuit Protection Type | OVERCURRENT THIRD LOCATION |
| Circuit Protection Type | OVERCURRENT SECOND LOCATION |
| Circuit Protection Type | OVERVOLTAGE FOURTH LOCATION |
| Body Width | 3.015 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 4 |
| Mounting Surface to Terminal End Distance | 2.491 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| APL3331-512-9-1 | 5/9 Secondary reference U.S. Government activity |
| IULHK3331-5129-1 | 5/2 Secondary reference U.S. Government activity |
| APL3331-5129-1 | 5/9 Secondary reference U.S. Government activity |
| 359128 | 3/9 Design control — primary reference Sierra Technologies Inc Garden City Div |
NSN 5925-01-074-3043 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-074-3043: Reset Method: MANUAL; Internal Trip Release Configuration: SHUNT TRIP FIRST LOCATION; Internal Trip Release Configuration: SHUNT TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP FOURTH LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.