PartsTable TECHNICAL DATA SHEET
NSN 5925-01-073-9228Government record, cited

Circuit Breaker5925-01-073-9228

NSN 5925-01-073-9228 · NIIN 010739228
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-073-9228 · 5925010739228 · NIIN 010739228 · 01-073-9228 · FSC 5925 Circuit Breakers · WC375/07-002 · W-C-375/7
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 TERMINAL
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.740 INCHES NOMINAL IN
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-073-9228
  • NIIN: 010739228
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-073-9228, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-073-9228
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 TERMINAL
Actuator Position DesignationAT EACH POLE
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.740 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.193 INCHES MINIMUM AND 2.241 INCHES MAXIMUM IN
Body Height2.371 INCHES MINIMUM AND 2.433 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps10000.0 AC ALL LOCATIONS
Specification/standard Data81348-W-C-375/7 GOVERNMENT SPECIFICATION
Body Length3.025 INCHES MINIMUM AND 3.065 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity3 TOGGLE
Inclosure Protection Type for Which DesignedCORROSION RESISTANT
Test Data Document81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity3 CLIP AND 3 COMPRESSION
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-150-3512 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-221-0677 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
WC375/07-002 2/2 Government specification standardization
U.S. Government activity
W-C-375/7 4/1 Identification reference
U.S. Government activity
Related Parts
5925-01-150-3512POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-221-0677POSSIBLE MATCH
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-073-9228?

NSN 5925-01-073-9228 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-073-9228?

2 possible matches (shared part number, not a government interchangeability claim): 5925-01-150-3512, 5925-01-221-0677. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-073-9228?

Key specifications for 5925-01-073-9228: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 TERMINAL; Actuator Position Designation: AT EACH POLE. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-073-9228 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.