The Circuit Breaker, cataloged under National Stock Number 5925-01-067-2924, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Sae International Dba Sae International. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 2 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-067-2924 |
| Primary Part Number | MS26574-2-1/2A |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Sae International Dba Sae International |
| Status | ACTIVE |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Thread Series Designator | UN |
| Reset Method | MANUAL |
| Maximum Continuous Load Current Rating Per Pole | 2.5 AMPERES AC AND 2.5 AMPERES DC SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 PUSH-PULL |
| Switch Voltage Rating and Type in Volts | 115.0 AC AND 28.0 DC |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND MOISTURE RESISTANT |
| Actuator Function | TRIP-RESET |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Specification/standard Data | 96906-MS26574 GOVERNMENT SPECIFICATION |
| Switch Current Rating and Type in Amps | 2.5 AC AND 2.5 DC |
| Actuator Position Designation | AT POLE ONE |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 100.0 AC AND 100.0 DC SINGLE LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 145.0 SINGLE LOCATION |
| Switch Terminal Type | TAB, SOLDER LUG |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Switch Location and Position Designation | EXTERNAL AT POLE ONE |
| Terminal Type and Quantity | 2 SCREW |
| Test Data Document | 81349-MIL-C-5809 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Nominal Thread Size | 0.438 INCHES IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Auxiliary Switch Function and Quantity | 1 CONTROL |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 28.0 DC SINGLE LOCATION |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Body Length | 0.749 INCHES MINIMUM AND 0.780 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Mounting Surface to Terminal End Distance | 1.494 INCHES MINIMUM AND 1.525 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| MIL-C-5809 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| MS26574-2-1-2 | Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M |
| SAE-AS58091 | Sae International Dba Sae International (USA) |
| 7274-4-2 1/2 | Sensata Technologies, Inc. Div Sensata Attleboro (USA) |
| MS26574-2-1/2A PRIMARY | Sae International Dba Sae International (USA) |
NSN 5925-01-067-2924 is a Circuit Breaker, manufactured by Sae International Dba Sae International, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-01-067-2924 has 5 cross-referenced part numbers: MIL-C-5809 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), MS26574-2-1-2 (Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M), SAE-AS58091 (Sae International Dba Sae International), 7274-4-2 1/2 (Sensata Technologies, Inc. Div Sensata Attleboro), MS26574-2-1/2A (Sae International Dba Sae International).
There are 2 known substitutes for 5925-01-067-2924: 5925-00-998-1633, 5925-01-148-5404. Verify interchangeability with system specifications before substitution.
Key specifications for MS26574-2-1/2A: Main Contact Tripping Mechanism Type: TRIP FREE; Trip Release Ambient Temp Rating: 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC; Circuit Protection Type: OVERCURRENT SINGLE LOCATION; Thread Series Designator: UN. 30 total characteristics are documented in the Federal Logistics Information System.