The Circuit Breaker, cataloged under National Stock Number 5925-01-065-4090, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-065-4090 |
| Primary Part Number | 260-1015-010 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 28.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 12 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE, TWO, THREE, FOUR, FIVE, AND SIX LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.060 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 4.500 INCHES MAXIMUM IN |
| Pole Quantity | 6 |
| Mounting Surface to Terminal End Distance | 2.656 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC AND 50.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1500.0 AC AND 2000.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 2.490 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT AND 19.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 6 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.750 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND MOISTURE RESISTANT |
| Test Data Document | 13499-260-1015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 12 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 260-1015-010 PRIMARY | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems (USA) |
| Reference | Meaning |
|---|---|
| APL-2783-1 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-065-4090 is a Circuit Breaker, manufactured by Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-065-4090 has 1 manufacturer part number on file: 260-1015-010 (Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems).
Key specifications for 260-1015-010: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 28.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 12 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.