The Circuit Breaker, cataloged under National Stock Number 5925-01-058-1265, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 8 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-058-1265 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 28.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 UNTHREADED HOLE(S) |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 0.750 POUNDS NOMINAL LBS |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 115.0 AC AND 28.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 145.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.940 INCHES NOMINAL IN |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 1.200 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.167 INCHES MINIMUM AND 0.177 INCHES MAXIMUM IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 4.260 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC AND 50.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3600.0 AC AND 3600.0 DC SINGLE LOCATION |
| Specification/standard Data | 81349-MIL-C-83383/2 GOVERNMENT SPECIFICATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 13.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Switch Current Rating and Type in Amps | 3.0 AC AND 3.0 DC |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND FUNGUS RESISTANT |
| Test Data Document | 81349--83383/02-09 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| SM600BA50A1 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| MIL-C-83383/2 | 5/9 Secondary reference U.S. Government activity |
| MIL-PRF-83383/2D | 5/9 Secondary reference U.S. Government activity |
| MIL-PRF-83383/2 | 4/1 Identification reference U.S. Government activity |
| 6510-002-50 | C/1 Advisory reference — outside the item-of-supply concept Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use CAGE Code 81640 for Cataloging |
| M83383/02-09 | 2/2 Government specification standardization U.S. Government activity |
NSN 5925-01-058-1265 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
8 possible matches (shared part number, not a government interchangeability claim): 5925-01-197-4686, 5925-01-197-4687, 5925-01-254-2050. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-058-1265: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 28.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S). 29 specifications are documented in the U.S. Government catalog.