PartsTable TECHNICAL DATA SHEET
NSN 5925-01-055-9223Government record, cited

Circuit Breaker5925-01-055-9223

NSN 5925-01-055-9223 · NIIN 010559223
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-055-9223 · 5925010559223 · NIIN 010559223 · 01-055-9223 · FSC 5925 Circuit Breakers · BACC18L5A · 6760-17-5 · D6760-17-5 · BACC18L5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 400.0 ALL LOCATIONS
Identification
  • NSN: 5925-01-055-9223
  • NIIN: 010559223
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-055-9223, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-055-9223
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts120.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED HOLE(S)
Actuator Position DesignationAT POLE TWO
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.728 INCHES MINIMUM AND 0.758 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.780 INCHES MINIMUM AND 1.840 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.250 INCHES MAXIMUM IN
Body Height2.125 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length2.200 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current10.000 MINIMUM AT 200 PCT AND 65.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 PUSH-PULL
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.470 INCHES MINIMUM AND 1.502 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedCORROSION RESISTANT AND DUSTPROOF AND FUNGUS PROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
BACC18L5A 3/2 Design control — primary reference
U.S. Government activity
6760-17-5 5/2 Secondary reference
U.S. Government activity
D6760-17-5 5/9 Secondary reference
U.S. Government activity
BACC18L5 5/9 Secondary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-055-9223?

NSN 5925-01-055-9223 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-055-9223?

Key specifications for 5925-01-055-9223: Bushing Length: 0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-055-9223 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com