The Circuit Breaker, cataloged under National Stock Number 5925-01-050-9032, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-050-9032 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 500.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE TWO |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 3.000 INCHES MAXIMUM IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 9.875 INCHES MAXIMUM IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 9.000 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 9.031 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 250.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 10000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.250 INCHES IN |
| Specification/standard Data | 81349-MIL-C-17361 GOVERNMENT SPECIFICATION |
| Body Length | 11.000 INCHES MAXIMUM IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 3.000 INCHES MAXIMUM IN |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT |
| Test Data Document | 81349-MIL-C-17361 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Thread Quantity Per Inch | 20 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 50.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 6 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 315C574G26 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| MIL-DTL-17361/6 | 4/1 Identification reference U.S. Government activity |
| 315C574G26 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| AQB-A250-NH | 5/9 Secondary reference U.S. Government activity |
| AQB-A250-250NH | 2/2 Government specification standardization U.S. Government activity |
| MIL-C-17361 | 5/9 Secondary reference U.S. Government activity |
NSN 5925-01-050-9032 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
3 possible matches (shared part number, not a government interchangeability claim): 5925-01-335-7098, 5925-01-493-2196, 5925-01-493-2197. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-050-9032: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 500.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.