Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.187 INCHES MINIMUM AND 0.249 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: RELAY TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 28.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 400.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-044-9166
  • NIIN: 010449166
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-044-9166, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-044-9166
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.187 INCHES MINIMUM AND 0.249 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationRELAY TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts200.0 AC AND 28.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Frequency in Hertz400.0 SINGLE LOCATION
Unpackaged Unit Weight0.200 POUNDS NOMINAL LBS
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.800 INCHES MINIMUM AND 1.820 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.760 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.370 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC AND 10.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC AND 5000.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Specification/standard Data96906-MS24571 GOVERNMENT STANDARD
Body Length2.189 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current18.000 MINIMUM AT 200 PCT AND 42.0000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedCORROSION RESISTANT AND HERMETICALLY SEALED AND EXPLOSION PROOF AND HUMIDITY RESISTANT AND SALT SPRAY PROOF AND SAND RESISTANT AND DUSTPROOF AND VIBRATIONPROOF AND SHOCK RESISTANT AND FUNGUS RESISTANT
Test Data Document81349-MIL-C-27715 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-DTL-27715 4/1 Identification reference
U.S. Government activity
6752-12-10 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
MS24571-10V 2/2 Government specification standardization
U.S. Government activity
MIL-C-27715 5/9 Secondary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-044-9166?

NSN 5925-01-044-9166 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-044-9166?

Key specifications for 5925-01-044-9166: Bushing Length: 0.187 INCHES MINIMUM AND 0.249 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: RELAY TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 28.0 DC SINGLE LOCATION. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-044-9166 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.