PartsTable TECHNICAL DATA SHEET
NSN 5925-01-043-5270Government record, cited

Circuit Breaker5925-01-043-5270

NSN 5925-01-043-5270 · NIIN 010435270
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-043-5270 · 5925010435270 · NIIN 010435270 · 01-043-5270 · FSC 5925 Circuit Breakers · WC375/04-002 · W-C-375/4
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 TERMINAL
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.738 INCHES MINIMUM AND 0.748 INCHES MAXIMUM IN
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-043-5270
  • NIIN: 010435270
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-043-5270, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-043-5270
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 TERMINAL
Actuator Position DesignationAT POLE TWO
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.738 INCHES MINIMUM AND 0.748 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.230 INCHES NOMINAL IN
Body Height2.650 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole80.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps10000.0 AC ALL LOCATIONS
Specification/standard Data81348-W-C-375/4 GOVERNMENT SPECIFICATION
Body Length6.250 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current6.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedCORROSION RESISTANT
Test Data Document81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity3 CLIP AND 3 COMPRESSION
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.220 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
WC375/04-002 2/2 Government specification standardization
U.S. Government activity
W-C-375/4 4/1 Identification reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-043-5270?

NSN 5925-01-043-5270 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-043-5270?

Key specifications for 5925-01-043-5270: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 TERMINAL; Actuator Position Designation: AT POLE TWO. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-043-5270 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com