The Tripper,circuit Breaker, cataloged under National Stock Number 5925-01-038-0677, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Schneider Electric Usa, Inc.. Government technical data includes 15 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-038-0677 |
| Primary Part Number | FA-M01 |
| Item Name | Tripper,circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Schneider Electric Usa, Inc. |
| Status | ACTIVE |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 120.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S)4 UNTHREADED HOLE(S) |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Body Style | RECTANGULAR DIMENSIONAL ENVELOPERECTANGULAR DIMENSIONAL ENVELOPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Unthreaded Mounting Hole Diameter | 0.219 INCHES NOMINAL0.219 INCHES NOMINAL IN |
| Pole Quantity | 33 |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.750 MINIMUM AT 200 PCT AND 1.150 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 6 SCREW |
| Trip Release Method | THERMAL ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| FA-M01 PRIMARY | Schneider Electric Usa, Inc. (USA) |
| Reference | Meaning |
|---|---|
| FA-M01 | 5/9 Secondary reference Schneider Electric Usa, Inc. |
| 10060993-101 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-038-0677 is a Tripper,circuit Breaker, manufactured by Schneider Electric Usa, Inc., classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-038-0677 has 1 manufacturer part number on file: FA-M01 (Schneider Electric Usa, Inc.).
Key specifications for FA-M01: Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)4 UNTHREADED HOLE(S); Overall Height: 4.500 INCHES NOMINAL4.500 INCHES NOMINAL IN. 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.