PartsTable TECHNICAL DATA SHEET
NSN 5925-01-033-1978Government record, cited

Circuit Breaker5925-01-033-1978

NSN 5925-01-033-1978 · NIIN 010331978
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-033-1978 · 5925010331978 · NIIN 010331978 · 01-033-1978 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SHUNT TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 60.0 OR 400.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-033-1978
  • NIIN: 010331978
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-033-1978, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-033-1978
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSHUNT TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 50.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE ONE
Frequency in Hertz60.0 OR 400.0 SINGLE LOCATION
Unpackaged Unit Weight1.800 OUNCES NOMINAL OZ
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 SINGLE LOCATION
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.625 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance1.605 INCHES MAXIMUM IN
Thread Pitch Diameters+0.3503 TO 0.3537 INCHES IN
Maximum Continuous Load Current Rating Per Pole1.25 AMPERES AC AND 1.25 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC AND 1000.0 DC SINGLE LOCATION
Nominal Thread Size0.375 INCHES IN
Body Length1.562 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedHERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Terminal Type and Quantity3 WIRE HOOK
Special Handling FeatureMAGNETIC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
AP-1-3-71F-1251 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-033-1978?

NSN 5925-01-033-1978 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-033-1978?

Key specifications for 5925-01-033-1978: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SHUNT TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-033-1978 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com