Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Switch Terminal Type: TAB, SOLDER LUG
  • Frequency in Hertz: 60.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-024-3807
  • NIIN: 010243807
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-024-3807, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-024-3807
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts120.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz60.0 SINGLE LOCATION
Unpackaged Unit Weight4.250 OUNCES NOMINAL OZ
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Switch Voltage Rating and Type in Volts250.0 AC AND 50.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Switch Location and Position DesignationINTERNAL AT POLE ONE
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole2.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 AC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.200 MINIMUM AT 200 PCT AND 0.650 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps2.5 AC AND 1.0 DC
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
CP35-5-70-2J7P 7/2 Vendor item drawing reference
Lockheed Martin Corporation Dba Lockheed Martin Div Rotary and Mission Systems
AM12HK2-120VACCURVE16 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-024-3807?

NSN 5925-01-024-3807 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-024-3807?

Key specifications for 5925-01-024-3807: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-024-3807 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com