The Circuit Breaker, cataloged under National Stock Number 5925-01-024-3343, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-024-3343 |
| Primary Part Number | 165215-2 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Raytheon Company |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.906 INCHES MAXIMUM IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.562 INCHES MAXIMUM IN |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 1.828 INCHES MAXIMUM IN |
| Thread Pitch Diameters | +0.3503 TO 0.3537 INCHES IN |
| Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.937 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 6 WIRE HOOK |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNEF |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 1.500 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 165215-2 PRIMARY | Raytheon Company (USA) |
| Reference | Meaning |
|---|---|
| AP112-1486-2 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-024-3343 is a Circuit Breaker, manufactured by Raytheon Company, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-024-3343 has 1 manufacturer part number on file: 165215-2 (Raytheon Company).
Key specifications for 165215-2: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.