The Circuit Breaker, cataloged under National Stock Number 5925-01-019-9696, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-019-9696 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | RELAY TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 SLOT |
| Actuator Position Designation | AT POLE ONE |
| Ultimate Trip Time Per Pole in Seconds | 105.000 MINIMUM AND 150.000 MAXIMUM SINGLE LOCATION |
| Frequency in Hertz | 60.0 SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.312 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 1.469 INCHES NOMINAL IN |
| Body Height | 2.640 INCHES NOMINAL IN |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 4.75 AMPERES AC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1500.0 AC SINGLE LOCATION |
| Body Length | 3.219 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 175.000 MINIMUM AT 125 PCT AND 600.000 MAXIMUM AT 125 PCT AND 100.000 MINIMUM AT 150 PCT AND 300.000 MAXIMUM AT 150 PCT AND 40.000 MINIMUM AT 200 PCT AND 140.000 MAXIMUM AT 200 PCT AND 20.000 MINIMUM AT 300 PCT AND 50.000 MAXIMUM AT 300 PCT AND 6.500 MINIMUM AT 400 PCT AND 10.750 MAXIMUM AT 400 PCT AND 4.000 MINIMUM AT 500 PCT AND 10.000 MAXIMUM AT 500 PCT AND 0.030 MINIMUM AT 1000 PCT AND 0.080 MAXIMUM AT 1000 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 1 THREADED STUD AND 2 SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Boss Height | 0.125 INCHES NOMINAL IN |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 2.500 INCHES NOMINAL IN |
| Mounting Slot Width | 0.164 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 8131RTV | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-019-9696 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-019-9696: Reset Method: MANUAL; Internal Trip Release Configuration: RELAY TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 SLOT. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.