PartsTable TECHNICAL DATA SHEET
NSN 5925-01-017-4987Government record, cited

Circuit Breaker5925-01-017-4987

NSN 5925-01-017-4987 · NIIN 010174987
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-017-4987 · 5925010174987 · NIIN 010174987 · 01-017-4987 · FSC 5925 Circuit Breakers · AM33MG6-5-50-4DC · AM2-Z18-43 · 351-610-043 · M55629/3-043 · MIL-C-55629/3
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Center to Center Distance Between Terminals Parallel to Width: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-017-4987
  • NIIN: 010174987
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-017-4987, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-017-4987
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts50.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Center to Center Distance Between Terminals Parallel to Width0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE AND TWO LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Mounting Surface to Terminal End Distance2.553 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 DC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Specification/standard Data81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
Body Length2.510 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.500 MINIMUM AT 200 PCT AND 8.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity2 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedSHOCK RESISTANT AND VIBRATION RESISTANT
Test Data Document81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5915-01-330-648416B110A POSSIBLE MATCH
FILTER,BAND PASS
Possible match (shared part number)Microsemi Corp. - High Performance Timing Dba Vectron International- Cancelled
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
AM33MG6-5-50-4DC C/1 Advisory reference — outside the item-of-supply concept
Eaton Corp Heinemann Products Commercial Controls Div
AM2-Z18-43 C/1 Advisory reference — outside the item-of-supply concept
Eaton Corp Heinemann Products Commercial Controls Div
351-610-043 C/1 Advisory reference — outside the item-of-supply concept
L3harris Interstate Electronics Corporation
M55629/3-043 2/2 Government specification standardization
U.S. Government activity
MIL-C-55629/3 5/9 Secondary reference
U.S. Government activity
MIL-PRF-55629/3 4/1 Identification reference
U.S. Government activity
16B110 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
Related Parts
5915-01-330-6484POSSIBLE MATCH
FILTER,BAND PASS
16B110A

Frequently Asked Questions

What is NSN 5925-01-017-4987?

NSN 5925-01-017-4987 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-017-4987?

1 possible match (shared part number, not a government interchangeability claim): 5915-01-330-6484. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-017-4987?

Key specifications for 5925-01-017-4987: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-017-4987 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com