PartsTable TECHNICAL DATA SHEET
NSN 5925-01-009-9797Government record, cited

Circuit Breaker5925-01-009-9797

NSN 5925-01-009-9797 · NIIN 010099797
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-009-9797 · 5925010099797 · NIIN 010099797 · 01-009-9797 · FSC 5925 Circuit Breakers · AM33MG6-10-250-4-60 · G330003-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC AND 50.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Unpackaged Unit Weight: 0.547 POUNDS NOMINAL LBS
Identification
  • NSN: 5925-01-009-9797
  • NIIN: 010099797
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-009-9797, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-009-9797
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 AC AND 50.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Frequency in Hertz60.0 ALL LOCATIONS
Unpackaged Unit Weight0.547 POUNDS NOMINAL LBS
Center to Center Distance Between Terminals Parallel to Width0.720 INCHES MINIMUM AND 0.740 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE AND TWO LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.520 INCHES MINIMUM AND 1.540 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Mounting Surface to Terminal End Distance2.430 INCHES MINIMUM AND 2.570 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC AND 10.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC AND 2000.0 DC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length2.520 INCHES MINIMUM AND 2.540 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.200 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity2 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.720 INCHES MINIMUM AND 0.740 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT
Precious Material and LocationCONTACT SURFACES SILVER
Thread Quantity Per Inch32
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
AM33MG6-10-250-4-60 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
G330003-1 7/2 Vendor item drawing reference
L3harris Technologies, Inc Div Space & Airborne Systems
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-009-9797?

NSN 5925-01-009-9797 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-009-9797?

Key specifications for 5925-01-009-9797: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC AND 50.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-009-9797 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com