The Circuit Breaker, cataloged under National Stock Number 5925-01-007-9407, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-007-9407 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.250 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Ultimate Trip Time Per Pole in Seconds | 60.000 NOMINAL SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.688 INCHES MINIMUM AND 0.750 INCHES MAXIMUM IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.250 INCHES MINIMUM AND 1.312 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3500.0 AC AND 4000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 1.313 INCHES MINIMUM AND 1.375 INCHES MAXIMUM IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Material | PLASTIC CASE |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Terminal Type and Quantity | 2 TAB W/SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNF |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 0.906 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 382-2074-2 | 3/9 Design control — primary reference Stellant Pst Corp. Dba Stellant Pst Corp. |
NSN 5925-01-007-9407 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-007-9407: Bushing Length: 0.250 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE SINGLE LOCATION; Mounting Facility Type and Quantity: 1 THREADED BUSHING. 24 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.