PartsTable TECHNICAL DATA SHEET
NSN 5925-01-007-9300Government record, cited

Circuit Breaker5925-01-007-9300

NSN 5925-01-007-9300 · NIIN 010079300
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-007-9300 · 5925010079300 · NIIN 010079300 · 01-007-9300 · FSC 5925 Circuit Breakers · 7MC7-3-050 · 7MC7-3-050
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.250 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: RELAY TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
  • Actuator Position Designation: AT POLE ONE
  • Unpackaged Unit Weight: 2.000 OUNCES NOMINAL OZ
Identification
  • NSN: 5925-01-007-9300
  • NIIN: 010079300
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-007-9300, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-007-9300
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.250 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationRELAY TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts32.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationAT POLE ONE
Unpackaged Unit Weight2.000 OUNCES NOMINAL OZ
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 SINGLE LOCATION
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.656 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance1.669 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole50.0 MILLIAMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2500.0 DC SINGLE LOCATION
Nominal Thread Size0.469 INCHES IN
Body Length1.781 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current0.006 MINIMUM AT 200 PCT AND 0.015 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity4 SCREW
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
7MC7-3-050 5/9 Secondary reference
U.S. Government activity
7MC7-3-050 3/9 Design control — primary reference
Texas Instruments Incorporated
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-007-9300?

NSN 5925-01-007-9300 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-007-9300?

Key specifications for 5925-01-007-9300: Bushing Length: 0.250 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: RELAY TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-007-9300 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com