PartsTable TECHNICAL DATA SHEET
NSN 5925-01-004-2790Government record, cited

Circuit Breaker5925-01-004-2790

NSN 5925-01-004-2790 · NIIN 010042790
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-004-2790 · 5925010042790 · NIIN 010042790 · 01-004-2790 · FSC 5925 Circuit Breakers · 7236-2-300 · 11654981 · 7236-2-300
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: AUTOMATIC
  • Operating Voltage Type and Rating Per Pole in Volts: 10.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S)
  • Body Style: RECTANGULAR DIMENSIONAL ENVELOPE
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 115.0 ALL LOCATIONS
  • Circuit Protection Type: OVERCURRENT ALL LOCATIONS
  • Pole Quantity: 3
Identification
  • NSN: 5925-01-004-2790
  • NIIN: 010042790
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-004-2790, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 12 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-004-2790
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodAUTOMATIC
Operating Voltage Type and Rating Per Pole in Volts10.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S)
Body StyleRECTANGULAR DIMENSIONAL ENVELOPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole300.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Trip Delay Time in Seconds Per Rated Continuous Current20.000 MINIMUM AT 200 PCT AND 200.000 MAXIMUM AT 200 PCT AND 0.100 MINIMUM AT 1000 PCT AND 3.000 MAXIMUM AT 1000 PCT ALL LOCATIONS
Terminal Type and Quantity3 SCREW
Trip Release MethodTHERMAL ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
7236-2-300 3/2 Design control — primary reference
U.S. Government activity
11654981 5/9 Secondary reference
U S Army Tank Automotive Command Amsta-Im-Mm
7236-2-300 5/9 Secondary reference
Sensata Technologies Inc Div Precision Products

Frequently Asked Questions

What is NSN 5925-01-004-2790?

NSN 5925-01-004-2790 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-004-2790?

Key specifications for 5925-01-004-2790: Reset Method: AUTOMATIC; Operating Voltage Type and Rating Per Pole in Volts: 10.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S); Overall Height: 1.625 INCHES NOMINAL IN. 12 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-004-2790 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com