PartsTable TECHNICAL DATA SHEET
NSN 5925-00-993-0370Government record, cited

Circuit Breaker5925-00-993-0370

NSN 5925-00-993-0370 · NIIN 009930370
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-993-0370 · 5925009930370 · NIIN 009930370 · 00-993-0370 · FSC 5925 Circuit Breakers · 1500-013-1 · BACC18K1501A · MP1501AC
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.250 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 28.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 400.0 SINGLE LOCATION
Identification
  • NSN: 5925-00-993-0370
  • NIIN: 009930370
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-993-0370, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-993-0370
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.250 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts200.0 AC AND 28.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Frequency in Hertz400.0 SINGLE LOCATION
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.807 INCHES MINIMUM AND 1.817 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.672 INCHES MINIMUM AND 0.702 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance1.859 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC AND 5000.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.187 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.400 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedEXPLOSION PROOF AND VIBRATIONPROOF
Test Data Document81205-BACC18K DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 TAB W/SCREW
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
1500-013-1 5/2 Secondary reference
U.S. Government activity
BACC18K1501A 3/2 Design control — primary reference
U.S. Government activity
MP1501AC 5/9 Secondary reference
Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use CAGE Code 81640 for Cataloging

Frequently Asked Questions

What is NSN 5925-00-993-0370?

NSN 5925-00-993-0370 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-993-0370?

Key specifications for 5925-00-993-0370: Bushing Length: 0.250 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 28.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-993-0370 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com