PartsTable TECHNICAL DATA SHEET
NSN 5925-00-993-0367Government record, cited

Circuit Breaker5925-00-993-0367

NSN 5925-00-993-0367 · NIIN 009930367
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-993-0367 · 5925009930367 · NIIN 009930367 · 00-993-0367 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
  • Frequency in Hertz: 400.0 SINGLE LOCATION
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 200.0 SINGLE LOCATION
  • Circuit Protection Type: OVERCURRENT SINGLE LOCATION
  • Pole Quantity: 1
Identification
  • NSN: 5925-00-993-0367
  • NIIN: 009930367
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-993-0367, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-993-0367
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts120.0 AC AND 30.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING
Frequency in Hertz400.0 SINGLE LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent200.0 SINGLE LOCATION
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC AND 10.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicINSTANTANEOUS AND TIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps3500.0 AC AND 6000.0 DC SINGLE LOCATION
Trip Delay Time in Seconds Per Rated Continuous Current0.200 MINIMUM AT 200 PCT AND 0.700 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedDUSTPROOF AND EXPLOSION PROOF
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 SCREW
Main Contact Tripping Mechanism TypeTRIP FREE
Trip Release MethodTHERMAL SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5330-01-541-59017274210 POSSIBLE MATCH
PARTS KIT,SEAL REPLACEMENT,MECHA
Possible match (shared part number)Elgin Sweeper Company
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
7274-2-10 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5330-01-541-5901POSSIBLE MATCH
PARTS KIT,SEAL REPLACEMENT,MECHA
7274210

Frequently Asked Questions

What is NSN 5925-00-993-0367?

NSN 5925-00-993-0367 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-00-993-0367?

1 possible match (shared part number, not a government interchangeability claim): 5330-01-541-5901. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-00-993-0367?

Key specifications for 5925-00-993-0367: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 1 THREADED BUSHING; Overall Height: 2.190 INCHES NOMINAL IN. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-993-0367 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com