The Circuit Breaker, cataloged under National Stock Number 5925-00-988-5474, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-988-5474 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 500.0 AC AND 250.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Actuator Position Designation | AT POLE TWO |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 1.675 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 8.750 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 5.000 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.281 INCHES NOMINAL IN |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 7.485 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC AND 50.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 10000.0 AC AND 10000.0 DC ALL LOCATIONS |
| Body Length | 10.000 INCHES MAXIMUM IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.675 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT |
| Test Data Document | 98453-5222247 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 50.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 6 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Boss Height | 0.188 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 609867PC69 | C/1 Advisory reference — outside the item-of-supply concept Naval Sea Systems Command |
| 5222247-501 | 5/9 Secondary reference Northrop Grumman Corp Electronic Systems Defensive System Div |
| ETN4920 | C/1 Advisory reference — outside the item-of-supply concept L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc. |
| AQBA100 | 3/2 Design control — primary reference U.S. Government activity |
| AQBA100STYLE1764 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| AQBA100STY1764-698 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-00-988-5474 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 5925-01-187-8766. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-00-988-5474: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 500.0 AC AND 250.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.