PartsTable TECHNICAL DATA SHEET
NSN 5925-00-957-0467Government record, cited

Circuit Breaker5925-00-957-0467

NSN 5925-00-957-0467 · NIIN 009570467
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-957-0467 · 5925009570467 · NIIN 009570467 · 00-957-0467 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION
  • Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC SECOND LOCATION
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S) AND 4 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE TWO
Identification
  • NSN: 5925-00-957-0467
  • NIIN: 009570467
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-957-0467, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-957-0467
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SECOND LOCATION
Internal Trip Release ConfigurationSERIES TRIP FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts200.0 AC FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts200.0 AC SECOND LOCATION
Mounting Facility Type and Quantity4 THREADED HOLE(S) AND 4 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE TWO
Switch Terminal TypeTHREADED STUD
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 FIRST LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SECOND LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Switch Location and Position DesignationEXTERNAL AT POLE THREE
Circuit Protection TypeOVERCURRENT FIRST LOCATION
Circuit Protection TypeOVERCURRENT SECOND LOCATION
Body Width2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM IN
Body Height2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.190 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole7.5 AMPERES AC FIRST LOCATION
Maximum Continuous Load Current Rating Per Pole7.5 AMPERES AC SECOND LOCATION
Trip Release CharacteristicTIME DELAY FIRST LOCATION
Trip Release CharacteristicTIME DELAY SECOND LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC FIRST LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC SECOND LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
3263S7-5AMP200VAC 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-957-0467?

NSN 5925-00-957-0467 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-957-0467?

Key specifications for 5925-00-957-0467: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-957-0467 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com