PartsTable TECHNICAL DATA SHEET
NSN 5925-00-918-3023Government record, cited

Circuit Breaker5925-00-918-3023

NSN 5925-00-918-3023 · NIIN 009183023 · Part number 260-2495-000
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 13499
Government record, cited
NSN 5925-00-918-3023 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-918-3023. Manufacturer of record part number: 260-2495-000.
Also searched as  5925-00-918-3023 · 5925009183023 · NIIN 009183023 · 00-918-3023 · FSC 5925 Circuit Breakers · CAGE 13499 · 260-2495-000 · 1163S50-125VDC3
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 125.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S) AND 4 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Fragility Factor: MODERATELY RUGGED
  • Body Style: SINGLE POLE TYPE
Identification
  • NSN: 5925-00-918-3023
  • NIIN: 009183023
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 260-2495-000
  • Manufacturer: Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-918-3023, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-918-3023
Primary Part Number260-2495-000
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerRockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts125.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity4 THREADED HOLE(S) AND 4 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM IN
Body Height2.678 INCHES MINIMUM AND 2.698 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.190 INCHES NOMINAL IN
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole50.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.180 MINIMUM AT 200 PCT AND 0.450 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedDUSTPROOF AND FUNGUS PROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 COMPRESSION
Main Contact Tripping Mechanism TypeTRIP FREE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
260-2495-000 PRIMARY Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems (USA)
Reference documents
ReferenceMeaning
1163S50-125VDC3 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-918-3023?

NSN 5925-00-918-3023 is a Circuit Breaker, manufactured by Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-918-3023?

NSN 5925-00-918-3023 has 1 manufacturer part number on file: 260-2495-000 (Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems).

What are the specifications of 260-2495-000?

Key specifications for 260-2495-000: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 125.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 4 THREADED HOLE(S) AND 4 UNTHREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-918-3023 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.