PartsTable TECHNICAL DATA SHEET
NSN 5925-00-906-0992Government record, cited

Circuit Breaker5925-00-906-0992

NSN 5925-00-906-0992 · NIIN 009060992 · Part number HQP1015
Westinghouse Electric Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 79500
Government record, cited
NSN 5925-00-906-0992 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-906-0992. Manufacturer of record part number: HQP1015.
Also searched as  5925-00-906-0992 · 5925009060992 · NIIN 009060992 · 00-906-0992 · FSC 5925 Circuit Breakers · CAGE 79500 · HQP1015 · QNPL1015
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 TERMINAL
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 60.0 SINGLE LOCATION
  • Body Style: SINGLE POLE TYPE
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 125.0 SINGLE LOCATION
Identification
  • NSN: 5925-00-906-0992
  • NIIN: 009060992
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: HQP1015
  • Manufacturer: Westinghouse Electric Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-906-0992, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Westinghouse Electric Corp. Government technical data includes 26 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-906-0992
Primary Part NumberHQP1015
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerWestinghouse Electric Corp
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts120.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity1 TERMINAL
Actuator Position DesignationAT POLE ONE
Frequency in Hertz60.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width1.000 INCHES MAXIMUM IN
Body Height2.375 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC SINGLE LOCATION
Body Length2.875 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current10.000 MINIMUM AT 200 PCT AND 115.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS MAXIMUM SINGLE LOCATION DEGC
Terminal Type and Quantity1 CLIP AND 1 COMPRESSION
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.187 INCHES NOMINAL IN
Trip Release MethodTHERMAL-MAGNETIC SINGLE LOCATION
Mounting Slot Width0.562 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
HQP1015 PRIMARY Westinghouse Electric Corp (USA)
Reference documents
ReferenceMeaning
HQP1015 5/2 Secondary reference
U.S. Government activity
QNPL1015 5/9 Secondary reference
Westinghouse Electric Corp
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-906-0992?

NSN 5925-00-906-0992 is a Circuit Breaker, manufactured by Westinghouse Electric Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-906-0992?

NSN 5925-00-906-0992 has 1 manufacturer part number on file: HQP1015 (Westinghouse Electric Corp).

What are the specifications of HQP1015?

Key specifications for HQP1015: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 1 TERMINAL; Actuator Position Designation: AT POLE ONE. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-906-0992 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com