The Circuit Breaker, cataloged under National Stock Number 5925-00-883-3843, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Us Army Aviation and Missile Command. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-883-3843 |
| Primary Part Number | 10607304-5 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Us Army Aviation and Missile Command |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 30.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 0.625 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.797 INCHES MINIMUM AND 1.827 INCHES MAXIMUM IN |
| Arc Quenching Method | AIR |
| Precious Material | SILVER |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.187 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 2.422 INCHES MINIMUM AND 2.452 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 100.0 AMPERES AC AND 100.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2500.0 AC AND 6000.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 2.631 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 3 PUSH-PULL |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM IN |
| Inclosure Protection Type for Which Designed | GENERAL PURPOSE |
| Precious Material and Location | CONTACT SURFACES SILVER |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 10607304-5 | Lockheed Martin Corporation Div Rotary and Mission Systems (USA) |
| 10607304-5 | Army, United States Department of the Dba Rock Island Arsenal Jmtc (USA) |
| 10607304-5 PRIMARY | Us Army Aviation and Missile Command (USA) |
| Reference | Meaning |
|---|---|
| 10607304-5 | 5/9 Secondary reference Lockheed Martin Corporation |
| 940-003-100 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-00-883-3843 is a Circuit Breaker, manufactured by Us Army Aviation and Missile Command, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-883-3843 has 3 manufacturer part numbers on file: 10607304-5 (Lockheed Martin Corporation Div Rotary and Mission Systems), 10607304-5 (Army, United States Department of the Dba Rock Island Arsenal Jmtc), 10607304-5 (Us Army Aviation and Missile Command).
Key specifications for 10607304-5: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 30.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.