Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.375 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 230.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE TWO
  • Ultimate Trip Time Per Pole in Seconds: 8.000 MINIMUM AND 15.500 MAXIMUM ALL LOCATIONS
Identification
  • NSN: 5925-00-875-0221
  • NIIN: 008750221
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-875-0221, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-875-0221
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.375 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts230.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE TWO
Ultimate Trip Time Per Pole in Seconds8.000 MINIMUM AND 15.500 MAXIMUM ALL LOCATIONS
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.625 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.875 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance1.780 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole3.5 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.500 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current1.000 MINIMUM AT 200 PCT AND 13.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND EXPLOSION RESISTANT AND HERMETICALLY SEALED
Test Data Document97942-788C689H25 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Terminal Type and Quantity6 WIRE HOOK
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
SM333-3-5-230VAC400C1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
788C689H25 7/2 Vendor item drawing reference
U.S. Government activity
79-146-25 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-875-0221?

NSN 5925-00-875-0221 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-875-0221?

Key specifications for 5925-00-875-0221: Bushing Length: 0.375 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 230.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-875-0221 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com