PartsTable TECHNICAL DATA SHEET
NSN 5925-00-863-4232Government record, cited

Circuit Breaker5925-00-863-4232

NSN 5925-00-863-4232 · NIIN 008634232 · Part number JA2S-A3-EB01DA-W-20-250AC-2
Heinemann Electric Canada Incdivision of Eaton Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE L3330
Government record, cited
NSN 5925-00-863-4232 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-863-4232. Manufacturer of record part number: JA2S-A3-EB01DA-W-20-250AC-2.
Also searched as  5925-00-863-4232 · 5925008634232 · NIIN 008634232 · 00-863-4232 · FSC 5925 Circuit Breakers · CAGE L3330 · JA2S-A3-EB01DA-W-20-250AC-2 · JA2-A3-20-2 · JA2A3-20-250-2A
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM IN
Identification
  • NSN: 5925-00-863-4232
  • NIIN: 008634232
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: JA2S-A3-EB01DA-W-20-250AC-2
  • Manufacturer: Heinemann Electric Canada Incdivision of Eaton Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-863-4232, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Heinemann Electric Canada Incdivision of Eaton Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-863-4232
Primary Part NumberJA2S-A3-EB01DA-W-20-250AC-2
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerHeinemann Electric Canada Incdivision of Eaton Corp
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE AND TWO LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.468 INCHES MINIMUM AND 1.532 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Mounting Surface to Terminal End Distance1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity2 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedDUSTPROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
JA2S-A3-EB01DA-W-20-250AC-2 Heinemann Electric Canada Incdivision of Eaton Corp (CAN)
Reference documents
ReferenceMeaning
JA2-A3-20-2 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
JA2A3-20-250-2A 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-863-4232?

NSN 5925-00-863-4232 is a Circuit Breaker, manufactured by Heinemann Electric Canada Incdivision of Eaton Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-863-4232?

NSN 5925-00-863-4232 has 1 manufacturer part number on file: JA2S-A3-EB01DA-W-20-250AC-2 (Heinemann Electric Canada Incdivision of Eaton Corp).

What are the specifications of JA2S-A3-EB01DA-W-20-250AC-2?

Key specifications for JA2S-A3-EB01DA-W-20-250AC-2: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-863-4232 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com