The Circuit Breaker, cataloged under National Stock Number 5925-00-826-8774, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-826-8774 |
| Primary Part Number | 66A73D22 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier |
| Status | ACTIVE |
| Bushing Length | 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 50.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| Center to Center Distance Between Terminals Parallel to Width | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.271 INCHES MINIMUM AND 1.291 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.690 INCHES MINIMUM AND 1.710 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 2.0 AMPERES DC SECOND LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 500.0 MILLIAMPERES DC FIRST LOCATION |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 500.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT AND 5.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | EXPLOSION RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 4 WIRE HOOK |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNEF |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 66A73D22 | Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier (USA) |
| Reference | Meaning |
|---|---|
| HE2-B3-RC0-5-LC2-50VDC-1 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| HE2-B3-RC0-5-LC2-50VDC-1 | 5/9 Secondary reference Pullman Mfg. Corporation |
| SM33-0-5-2-50VDC1 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-00-826-8774 is a Circuit Breaker, manufactured by Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-826-8774 has 1 manufacturer part number on file: 66A73D22 (Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier).
Key specifications for 66A73D22: Bushing Length: 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.