PartsTable TECHNICAL DATA SHEET
NSN 5925-00-809-1798Government record, cited

Circuit Breaker5925-00-809-1798

NSN 5925-00-809-1798 · NIIN 008091798
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-809-1798 · 5925008091798 · NIIN 008091798 · 00-809-1798 · FSC 5925 Circuit Breakers · 91427-6 · 6755-1-5 · D6755-1-5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.250 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 30.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 60.0 SINGLE LOCATION
Identification
  • NSN: 5925-00-809-1798
  • NIIN: 008091798
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-809-1798, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-809-1798
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.250 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts115.0 AC AND 30.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationAT POLE ONE
Frequency in Hertz60.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length0.782 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.750 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance0.813 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps500.0 AC AND 500.0 DC SINGLE LOCATION
Nominal Thread Size0.468 INCHES IN
Body Length1.094 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current15.000 MINIMUM AT 200 PCT AND 120.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH BUTTON
Inclosure Protection Type for Which DesignedEXPLOSION RESISTANT AND FUNGUS PROOF AND CORROSION RESISTANT
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionRESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 SCREW
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
91427-6 3/9 Design control — primary reference
U.S. Government activity
6755-1-5 5/2 Secondary reference
U.S. Government activity
D6755-1-5 5/9 Secondary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-00-809-1798?

NSN 5925-00-809-1798 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-809-1798?

Key specifications for 5925-00-809-1798: Bushing Length: 0.250 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC AND 30.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-809-1798 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com