The Circuit Breaker, cataloged under National Stock Number 5925-00-808-9233, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 11 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-808-9233 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 120.0 AC AND 30.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 0.100 POUNDS NOMINAL LBS |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 SINGLE LOCATION |
| Precious Material | SILVER |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.750 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.843 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC AND 3.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC AND 6000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.469 INCHES IN |
| Body Length | 1.187 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.400 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 PUSH-PULL |
| Inclosure Protection Type for Which Designed | EXPLOSION PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| Precious Material and Location | CONTACT SURFACES SILVER |
| Cubic Measure | 2.255 CUBIC INCHES |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| G355634-1 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| G305010-1 | 5/9 Secondary reference American Telephone and Telegraph Co |
| MP1505 | 5/9 Secondary reference Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use CAGE Code 81640 for Cataloging |
| MP1505DC8 | 5/9 Secondary reference Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use CAGE Code 81640 for Cataloging |
| 40-001010-07 | 5/9 Secondary reference Interlink Communications Inc |
| G305010-1 | 5/9 Secondary reference U.S. Government activity |
| 67C1807-3 | 3/2 Design control — primary reference U.S. Government activity |
| G355634-1 | 5/9 Secondary reference Drs Sustainment Systems, Inc. |
| G355634-1 | 5/9 Secondary reference Smiths Detection Inc. Dba Smiths Detection Inc Casc |
| 998738-06 | 5/9 Secondary reference Ge Aviation Systems Llc |
| 1500-052-3 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-00-808-9233 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 5325-01-276-0033. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-00-808-9233: Bushing Length: 0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.