The Circuit Breaker, cataloged under National Stock Number 5925-00-808-2017, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Div Rmd Strategic. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-808-2017 |
| Primary Part Number | 711570-13REVC |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Raytheon Company Div Rmd Strategic |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE ONE |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 60.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 0.312 POUNDS NOMINAL LBS |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 115.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 2.775 INCHES MINIMUM AND 2.955 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 7.5 AMPERES AC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Current Rating and Type in Amps | 5.0 AC AND 1.0 DC |
| Inclosure Protection Type for Which Designed | SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT |
| Test Data Document | 05869-711570 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 711570-13REVC PRIMARY | Raytheon Company Div Rmd Strategic (USA) |
| Reference | Meaning |
|---|---|
| 711570-13REVC | 5/2 Secondary reference U.S. Government activity |
| 70-132-15MG6 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| AM12HKMG3-7-5-50-250VAC4 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-00-808-2017 is a Circuit Breaker, manufactured by Raytheon Company Div Rmd Strategic, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-808-2017 has 1 manufacturer part number on file: 711570-13REVC (Raytheon Company Div Rmd Strategic).
Key specifications for 711570-13REVC: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.