PartsTable TECHNICAL DATA SHEET
NSN 5925-00-804-3480Government record, cited

Circuit Breaker5925-00-804-3480

NSN 5925-00-804-3480 · NIIN 008043480 · Part number L219716-3
Raytheon Company Dba Raytheon Co · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 06845
Government record, cited
NSN 5925-00-804-3480 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-804-3480. Manufacturer of record part number: L219716-3.
Also searched as  5925-00-804-3480 · 5925008043480 · NIIN 008043480 · 00-804-3480 · FSC 5925 Circuit Breakers · CAGE 06845 · L219716-3 · 70-123-3MG3
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Ultimate Trip Time Per Pole in Seconds: 70.000 NOMINAL SINGLE LOCATION
  • Switch Terminal Type: TURRET
Identification
  • NSN: 5925-00-804-3480
  • NIIN: 008043480
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: L219716-3
  • Manufacturer: Raytheon Company Dba Raytheon Co
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-804-3480, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Dba Raytheon Co. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-804-3480
Primary Part NumberL219716-3
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerRaytheon Company Dba Raytheon Co
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts120.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Ultimate Trip Time Per Pole in Seconds70.000 NOMINAL SINGLE LOCATION
Switch Terminal TypeTURRET
Frequency in Hertz60.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Switch Voltage Rating and Type in Volts115.0 AC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.062 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.750 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.997 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole500.0 MILLIAMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 AC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.500 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current9.000 NOMINAL AT 200 PCT AND 3.500 NOMINAL AT 300 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps5.0 AC
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT AND EXPLOSION RESISTANT
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
L219716-3 PRIMARY Raytheon Company Dba Raytheon Co (USA)
Reference documents
ReferenceMeaning
70-123-3MG3 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-804-3480?

NSN 5925-00-804-3480 is a Circuit Breaker, manufactured by Raytheon Company Dba Raytheon Co, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-804-3480?

NSN 5925-00-804-3480 has 1 manufacturer part number on file: L219716-3 (Raytheon Company Dba Raytheon Co).

What are the specifications of L219716-3?

Key specifications for L219716-3: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-804-3480 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.