PartsTable TECHNICAL DATA SHEET
NSN 5925-00-803-1928Government record, cited

Circuit Breaker5925-00-803-1928

NSN 5925-00-803-1928 · NIIN 008031928 · Part number 24-8942
Johnson Controls Navy Systems, Llc · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 66935
Government record, cited
NSN 5925-00-803-1928 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-803-1928. Manufacturer of record part number: 24-8942.
Also searched as  5925-00-803-1928 · 5925008031928 · NIIN 008031928 · 00-803-1928 · FSC 5925 Circuit Breakers · CAGE 66935 · 24-8942 · Y40-104AMG2
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 60.0 SINGLE LOCATION
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-00-803-1928
  • NIIN: 008031928
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 24-8942
  • Manufacturer: Johnson Controls Navy Systems, Llc
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-803-1928, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Johnson Controls Navy Systems, Llc. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-803-1928
Primary Part Number24-8942
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerJohnson Controls Navy Systems, Llc
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Frequency in Hertz60.0 SINGLE LOCATION
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.312 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width1.468 INCHES NOMINAL IN
Body Height2.656 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole60.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1500.0 AC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length3.218 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current0.300 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedGENERAL PURPOSE
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 COMPRESSION
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
24-8942 Johnson Controls Navy Systems, Llc (USA)
Reference documents
ReferenceMeaning
Y40-104AMG2 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-803-1928?

NSN 5925-00-803-1928 is a Circuit Breaker, manufactured by Johnson Controls Navy Systems, Llc, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-803-1928?

NSN 5925-00-803-1928 has 1 manufacturer part number on file: 24-8942 (Johnson Controls Navy Systems, Llc).

What are the specifications of 24-8942?

Key specifications for 24-8942: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-803-1928 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.