PartsTable TECHNICAL DATA SHEET
NSN 5925-00-620-3971Government record, cited

Circuit Breaker5925-00-620-3971

NSN 5925-00-620-3971 · NIIN 006203971
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-620-3971 · 5925006203971 · NIIN 006203971 · 00-620-3971 · FSC 5925 Circuit Breakers · ETN1064 · MIL-C-17588 · ALB5-30A
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC AND 125.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 2 THREADED STUD(S)
  • Actuator Position Designation: AT POLE TWO
  • Ultimate Trip Time Per Pole in Seconds: 3600.000 NOMINAL ALL LOCATIONS
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.125 INCHES NOMINAL IN
Identification
  • NSN: 5925-00-620-3971
  • NIIN: 006203971
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-620-3971, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-620-3971
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts125.0 AC AND 125.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity2 THREADED STUD(S)
Actuator Position DesignationAT POLE TWO
Ultimate Trip Time Per Pole in Seconds3600.000 NOMINAL ALL LOCATIONS
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.125 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length0.500 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width3.344 INCHES NOMINAL IN
Body Height3.375 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole30.0 AMPERES AC AND 30.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS AND TIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC AND 5000.0 DC ALL LOCATIONS
Nominal Thread Size0.216 INCHES IN
Body Length4.125 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current10.000 MINIMUM AT 125 PCT AND 100.000 MAXIMUM AT 125 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width2.937 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedSHOCKPROOF AND VIBRATIONPROOF
Test Data Document81349-MIL-C-17588 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Thread Quantity Per Inch24
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating50.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 QUICK DISCONNECT, MALE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
ETN1064 C/1 Advisory reference — outside the item-of-supply concept
L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.
MIL-C-17588 4/1 Identification reference
U.S. Government activity
ALB5-30A 2/2 Government specification standardization
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-620-3971?

NSN 5925-00-620-3971 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-620-3971?

Key specifications for 5925-00-620-3971: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC AND 125.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 THREADED STUD(S); Actuator Position Designation: AT POLE TWO. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-620-3971 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com