The Circuit Breaker, cataloged under National Stock Number 5925-00-596-2146, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Nederland. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-596-2146 |
| Primary Part Number | 352250009229 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Nederland |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| Ultimate Trip Time Per Pole in Seconds | 3.000 MINIMUM AND 60.000 MAXIMUM ALL LOCATIONS |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.625 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 120.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Switch Location and Position Designation | INTERNAL AT POLE TWO |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.281 INCHES MAXIMUM IN |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.828 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT AND 1.750 MAXIMUM AT 400 PCT AND 0.600 MAXIMUM AT 600 PCT AND 0.100 MAXIMUM AT 800 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 18 TOGGLE |
| Switch Current Rating and Type in Amps | 0.5 AC AND 0.5 DC |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT |
| Test Data Document | 81349-MILC39019-4 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 352250009229 | Thales Nederland (NLD) |
| Reference | Meaning |
|---|---|
| MILC39019-4 | 4/1 Identification reference U.S. Government activity |
| M39019/4-30 | 2/2 Government specification standardization U.S. Government activity |
NSN 5925-00-596-2146 is a Circuit Breaker, manufactured by Thales Nederland, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-596-2146 has 1 manufacturer part number on file: 352250009229 (Thales Nederland).
Key specifications for 352250009229: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.