PartsTable TECHNICAL DATA SHEET
NSN 5925-00-564-2113Government record, cited

Circuit Breaker5925-00-564-2113

NSN 5925-00-564-2113 · NIIN 005642113 · Part number JXD63B300/W60992/J6N1/TA2J6500
Siemens Energy and Automation Inc Ite Circuit Protection Div · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 66842
Government record, cited
NSN 5925-00-564-2113 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-564-2113. Manufacturer of record part number: JXD63B300/W60992/J6N1/TA2J6500.
Also searched as  5925-00-564-2113 · 5925005642113 · NIIN 005642113 · 00-564-2113 · FSC 5925 Circuit Breakers · CAGE 66842 · JXD63B300/W60992/J6N1/TA2J6500 · JJ3B300JL1N400 · JJ3-B300JL1N-400
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 3.000 INCHES NOMINAL IN
  • Body Style: MULTIPOLE-SINGLE ACTUATOR TYPE
Identification
  • NSN: 5925-00-564-2113
  • NIIN: 005642113
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: JXD63B300/W60992/J6N1/TA2J6500
  • Manufacturer: Siemens Energy and Automation Inc Ite Circuit Protection Div
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-564-2113, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Siemens Energy and Automation Inc Ite Circuit Protection Div. Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-564-2113
Primary Part NumberJXD63B300/W60992/J6N1/TA2J6500
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerSiemens Energy and Automation Inc Ite Circuit Protection Div
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts600.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE TWO
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width3.000 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length9.750 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width9.000 INCHES NOMINAL IN
Body Height4.062 INCHES NOMINAL IN
Unthreaded Mounting Hole Diameter0.250 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole300.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps22000.0 AC ALL LOCATIONS
Body Length11.000 INCHES NOMINAL IN
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width3.000 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 COMPRESSION
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.125 INCHES NOMINAL IN
Trip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length9.875 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
JXD63B300/W60992/J6N1/TA2J6500 PRIMARY Siemens Energy and Automation Inc Ite Circuit Protection Div (USA)
Reference documents
ReferenceMeaning
JJ3B300JL1N400 5/9 Secondary reference
L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.
JJ3-B300JL1N-400 5/9 Secondary reference
Siemens Energy and Automation Inc Ite Circuit Protection Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-564-2113?

NSN 5925-00-564-2113 is a Circuit Breaker, manufactured by Siemens Energy and Automation Inc Ite Circuit Protection Div, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-564-2113?

NSN 5925-00-564-2113 has 1 manufacturer part number on file: JXD63B300/W60992/J6N1/TA2J6500 (Siemens Energy and Automation Inc Ite Circuit Protection Div).

What are the specifications of JXD63B300/W60992/J6N1/TA2J6500?

Key specifications for JXD63B300/W60992/J6N1/TA2J6500: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-564-2113 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com