PartsTable TECHNICAL DATA SHEET
NSN 5925-00-500-6749Government record, cited

Circuit Breaker5925-00-500-6749

NSN 5925-00-500-6749 · NIIN 005006749
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-500-6749 · 5925005006749 · NIIN 005006749 · 00-500-6749 · FSC 5925 Circuit Breakers
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 240.0 AC SINGLE LOCATION
  • Actuator Position Designation: AT EACH POLE
  • Ultimate Trip Time Per Pole in Seconds: 300.000 NOMINAL SINGLE LOCATION
  • Frequency in Hertz: 60.0 SINGLE LOCATION
  • Body Style: SINGLE POLE TYPE
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 125.0 SINGLE LOCATION
Identification
  • NSN: 5925-00-500-6749
  • NIIN: 005006749
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-500-6749, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-500-6749
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts120.0 AC AND 240.0 AC SINGLE LOCATION
Actuator Position DesignationAT EACH POLE
Ultimate Trip Time Per Pole in Seconds300.000 NOMINAL SINGLE LOCATION
Frequency in Hertz60.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width3.375 INCHES NOMINAL IN
Body Height2.343 INCHES NOMINAL IN
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole40.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC SINGLE LOCATION
Body Length0.937 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current300.000 NOMINAL AT 125 PCT AND 25.000 NOMINAL AT 200 PCT AND 7.000 NOMINAL AT 300 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity1 SCREW BASE AND 1 QUICK DISCONNECT, MALE
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.218 INCHES NOMINAL IN
Trip Release MethodTHERMAL-MAGNETIC SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
3510-00-910-5992201509 POSSIBLE MATCH
ROLLER,DOOR HANDLE
Possible match (shared part number)Wascomat of America Div of Bermil Industries Corp
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
NA40 3/9 Design control — primary reference
Challenger Electrical Equipment Corp
Related Parts
3510-00-910-5992POSSIBLE MATCH
ROLLER,DOOR HANDLE
201509

Frequently Asked Questions

What is NSN 5925-00-500-6749?

NSN 5925-00-500-6749 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-00-500-6749?

1 possible match (shared part number, not a government interchangeability claim): 3510-00-910-5992. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-00-500-6749?

Key specifications for 5925-00-500-6749: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 240.0 AC SINGLE LOCATION; Actuator Position Designation: AT EACH POLE; Ultimate Trip Time Per Pole in Seconds: 300.000 NOMINAL SINGLE LOCATION. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-500-6749 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com