The Circuit Breaker, cataloged under National Stock Number 5925-00-497-1860, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-497-1860 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | AUTOMATIC |
| Operating Voltage Type and Rating Per Pole in Volts | 30.0 DC SINGLE LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Pole Quantity | 11 |
| Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2500.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT AND 3600.000 NOMINAL AT 138 PCT SINGLE LOCATION |
| Thread Quantity Per Inch | 3232 |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Terminal Type and Quantity | 2 SCREW |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| MILC7079 | 4/1 Identification reference U.S. Government activity |
| AN3160-35L | 2/2 Government specification standardization U.S. Government activity |
NSN 5925-00-497-1860 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-00-497-1860: Reset Method: AUTOMATIC; Operating Voltage Type and Rating Per Pole in Volts: 30.0 DC SINGLE LOCATION; Overall Height: 2.875 INCHES NOMINAL2.875 INCHES NOMINAL IN; Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 138.0 SINGLE LOCATION. 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.