Circuit Breaker5925-00-491-2686

NSN 5925-00-491-2686 · NIIN 004912686
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-491-2686 · 5925004912686 · NIIN 004912686 · 00-491-2686 · FSC 5925 Circuit Breakers · 918207-1 · AP12N4-152-1 · AP12-470-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.330 INCHES MINIMUM AND 0.330 INCHES MINIMUM AND 0.380 INCHES MAXIMUM0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING1 THREADED BUSHING
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 400.0 ALL LOCATIONS
Identification
  • NSN: 5925-00-491-2686
  • NIIN: 004912686
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-491-2686, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-491-2686
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.330 INCHES MINIMUM AND 0.330 INCHES MINIMUM AND 0.380 INCHES MAXIMUM0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING1 THREADED BUSHING
Actuator Position DesignationAT EACH POLE
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.620 INCHES NOMINAL0.620 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPEMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.250 INCHES MAXIMUM1.250 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
Pole Quantity22
Mounting Surface to Terminal End Distance1.780 INCHES MAXIMUM1.780 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole1.5 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.500 INCHES MAXIMUM1.500 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.007 MINIMUM AT 200 PCT AND 0.025 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Thread Quantity Per Inch3232
MaterialPLASTIC CASE
Actuator FunctionRESET
Terminal Type and Quantity4 WIRE HOOK
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNEF
Trip Release MethodMAGNETIC ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Length0.880 INCHES NOMINAL0.880 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
918207-1 3/2 Design control — primary reference
U.S. Government activity
AP12N4-152-1 5/9 Secondary reference
U.S. Government activity
AP12-470-1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-491-2686?

NSN 5925-00-491-2686 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-491-2686?

Key specifications for 5925-00-491-2686: Bushing Length: 0.330 INCHES MINIMUM AND 0.330 INCHES MINIMUM AND 0.380 INCHES MAXIMUM0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-491-2686 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com