PartsTable TECHNICAL DATA SHEET
NSN 5925-00-490-7919Government record, cited

Circuit Breaker5925-00-490-7919

NSN 5925-00-490-7919 · NIIN 004907919 · Part number 060-003020
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 26916
Government record, cited
NSN 5925-00-490-7919 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-490-7919. Manufacturer of record part number: 060-003020.
Also searched as  5925-00-490-7919 · 5925004907919 · NIIN 004907919 · 00-490-7919 · FSC 5925 Circuit Breakers · CAGE 26916 · 060-003020 · AP1-1-52-253 · AP1-7409-1 · 77-161-1 · SM3+25DC1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 28.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE ONE
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-00-490-7919
  • NIIN: 004907919
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 060-003020
  • Manufacturer: Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-490-7919, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-490-7919
Primary Part Number060-003020
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerNorthrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple
StatusACTIVE
Bushing Length0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts28.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE ONE
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 SINGLE LOCATION
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM IN
Thread Pitch Diameters+0.3503 TO 0.3537 INCHES IN
Maximum Continuous Load Current Rating Per Pole25.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps750.0 AC SINGLE LOCATION
Nominal Thread Size0.375 INCHES IN
Body Length1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current1.000 MINIMUM AT 200 PCT AND 5.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND EXPLOSION RESISTANT AND HERMETICALLY SEALED
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 WIRE HOOK
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNEF
Trip Release MethodMAGNETIC-HYDRAULIC SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
060-003020 PRIMARY Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple (USA)
Reference documents
ReferenceMeaning
AP1-1-52-253 5/2 Secondary reference
U.S. Government activity
AP1-7409-1 5/2 Secondary reference
U.S. Government activity
77-161-1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
SM3+25DC1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
SM3-25-28VDC1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-490-7919?

NSN 5925-00-490-7919 is a Circuit Breaker, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-490-7919?

NSN 5925-00-490-7919 has 1 manufacturer part number on file: 060-003020 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple).

What are the specifications of 060-003020?

Key specifications for 060-003020: Bushing Length: 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 28.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-490-7919 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com