PartsTable TECHNICAL DATA SHEET
NSN 5925-00-488-9178Government record, cited

Circuit Breaker5925-00-488-9178

NSN 5925-00-488-9178 · NIIN 004889178
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-488-9178 · 5925004889178 · NIIN 004889178 · 00-488-9178 · FSC 5925 Circuit Breakers · 7234-34-5 · 63213-9 · 7274-34-5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.359 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE ONE
  • Switch Terminal Type: TAB, SOLDER LUG
Identification
  • NSN: 5925-00-488-9178
  • NIIN: 004889178
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-488-9178, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-488-9178
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.359 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts120.0 AC AND 30.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE ONE
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz400.0 SINGLE LOCATION
Unpackaged Unit Weight1.000 OUNCES NOMINAL OZ
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Switch Voltage Rating and Type in Volts120.0 AC AND 30.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent145.0 SINGLE LOCATION
Switch Location and Position DesignationINTERNAL AT POLE ONE
Precious MaterialGOLD
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.750 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance1.420 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2500.0 AC AND 2500.0 DC SINGLE LOCATION
Nominal Thread Size0.469 INCHES IN
Body Length1.287 INCHES MINIMUM AND 1.317 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Switch Current Rating and Type in Amps2.0 AC AND 3.0 DC
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND EXPLOSION PROOF
Precious Material and LocationAUXILIARY TERMINALS GOLD
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
7234-34-5 5/9 Secondary reference
U.S. Government activity
63213-9 3/2 Design control — primary reference
U.S. Government activity
7274-34-5 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-488-9178?

NSN 5925-00-488-9178 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-488-9178?

Key specifications for 5925-00-488-9178: Bushing Length: 0.359 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-488-9178 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com