PartsTable TECHNICAL DATA SHEET
NSN 5925-00-471-4635Government record, cited

Circuit Breaker5925-00-471-4635

NSN 5925-00-471-4635 · NIIN 004714635 · Part number 905439-2
General Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 05257
Government record, cited
NSN 5925-00-471-4635 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-471-4635. Manufacturer of record part number: 905439-2.
Also searched as  5925-00-471-4635 · 5925004714635 · NIIN 004714635 · 00-471-4635 · FSC 5925 Circuit Breakers · CAGE 05257 · 905439-2 · AP112R767-1 · AP112R767-2
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.380 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION
  • Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION
  • Internal Trip Release Configuration: RELAY TRIP FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
Identification
  • NSN: 5925-00-471-4635
  • NIIN: 004714635
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 905439-2
  • Manufacturer: General Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-471-4635, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is General Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-471-4635
Primary Part Number905439-2
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerGeneral Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems
StatusACTIVE
Bushing Length0.380 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SECOND LOCATION
Internal Trip Release ConfigurationSERIES TRIP THIRD LOCATION
Internal Trip Release ConfigurationRELAY TRIP FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationAT POLE TWO
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.625 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts120.0 AC AND 50.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Switch Location and Position DesignationINTERNAL AT POLE THREE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.937 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance1.828 INCHES MAXIMUM IN
Thread Pitch Diameters+0.3503 TO 0.3537 INCHES IN
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC THIRD LOCATION
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC FIRST LOCATION
Maximum Continuous Load Current Rating Per Pole7.5 AMPERES AC SECOND LOCATION
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.562 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.008 MINIMUM AT 200 PCT AND 0.300 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5930-01-253-612851763 POSSIBLE MATCH
SWITCH,PUSH
Possible match (shared part number)Ducommun Labarge Technologies, Inc Dba Ducommun Labarge Technologies, Inc
Cross-Reference Index
Part NumberManufacturer
905439-2 PRIMARY General Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems (CAN)
Reference documents
ReferenceMeaning
AP112R767-1 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
AP112R767-2 5/2 Secondary reference
U.S. Government activity
Related Parts
5930-01-253-6128POSSIBLE MATCH
SWITCH,PUSH
51763

Frequently Asked Questions

What is NSN 5925-00-471-4635?

NSN 5925-00-471-4635 is a Circuit Breaker, manufactured by General Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-471-4635?

NSN 5925-00-471-4635 has 1 manufacturer part number on file: 905439-2 (General Dynamics Land Systems - Canadacorporation Div General Dynamics Mission Systems).

What NSN replaces 5925-00-471-4635?

1 possible match (shared part number, not a government interchangeability claim): 5930-01-253-6128. Verify interchangeability with system specifications before substitution.

What are the specifications of 905439-2?

Key specifications for 905439-2: Bushing Length: 0.380 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-471-4635 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com