The Circuit Breaker, cataloged under National Stock Number 5925-00-465-9917, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-465-9917 |
| Primary Part Number | 168894-2 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Raytheon Company |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SHUNT TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 31.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Actuator Position Designation | AT POLE TWO |
| Unpackaged Unit Weight | 14.000 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.625 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.875 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 1.780 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES DC FIRST LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES DC THIRD LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 3.5 AMPERES DC SECOND LOCATION |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.500 INCHES MAXIMUM IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | HERMETICALLY SEALED |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 9 WIRE HOOK |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNEF |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 168894-2 PRIMARY | Raytheon Company (USA) |
| Reference | Meaning |
|---|---|
| AP333-285-2A | 5/2 Secondary reference U.S. Government activity |
| AP333-285-2 | 5/9 Secondary reference U.S. Government activity |
NSN 5925-00-465-9917 is a Circuit Breaker, manufactured by Raytheon Company, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-465-9917 has 1 manufacturer part number on file: 168894-2 (Raytheon Company).
Key specifications for 168894-2: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SHUNT TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 31.0 DC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.