The Circuit Breaker, cataloged under National Stock Number 5925-00-450-0137, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Us Army Aviation and Missile Command. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-450-0137 |
| Primary Part Number | 10158805-1 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Us Army Aviation and Missile Command |
| Status | ACTIVE |
| Bushing Length | 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 32.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE ONE |
| Switch Terminal Type | PIN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 28.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 135.0 SINGLE LOCATION |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.623 INCHES MINIMUM AND 1.653 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2500.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.469 INCHES IN |
| Body Length | 1.735 INCHES MINIMUM AND 1.765 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.100 MINIMUM AT 200 PCT AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 PUSH-PULL |
| Switch Current Rating and Type in Amps | 7.0 DC |
| Inclosure Protection Type for Which Designed | VIBRATION RESISTANT |
| Switch Contact Arrangement | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 10158805-1 PRIMARY | Us Army Aviation and Missile Command (USA) |
| Reference | Meaning |
|---|---|
| 7MC3-4-3 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-00-450-0137 is a Circuit Breaker, manufactured by Us Army Aviation and Missile Command, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-450-0137 has 1 manufacturer part number on file: 10158805-1 (Us Army Aviation and Missile Command).
Key specifications for 10158805-1: Bushing Length: 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.