PartsTable TECHNICAL DATA SHEET
NSN 5925-00-449-3622Government record, cited

Circuit Breaker5925-00-449-3622

NSN 5925-00-449-3622 · NIIN 004493622
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-449-3622 · 5925004493622 · NIIN 004493622 · 00-449-3622 · FSC 5925 Circuit Breakers · AP112-222-47 · 79-106-7 · 900486-547
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Ultimate Trip Time Per Pole in Seconds: 0.400 MINIMUM AND 2.000 MAXIMUM ALL LOCATIONS
  • Frequency in Hertz: 60.0 ALL LOCATIONS
Identification
  • NSN: 5925-00-449-3622
  • NIIN: 004493622
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-449-3622, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-449-3622
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Ultimate Trip Time Per Pole in Seconds0.400 MINIMUM AND 2.000 MAXIMUM ALL LOCATIONS
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.750 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.062 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.250 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance2.471 INCHES NOMINAL IN
Thread Pitch Diameters+0.1177 TO 0.1214 INCHES IN
Maximum Continuous Load Current Rating Per Pole9.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length2.500 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current0.130 MINIMUM AT 200 PCT AND 0.700 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity3 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.750 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedEXPLOSION RESISTANT
Test Data Document06481-900486 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
AP112-222-47 3/2 Design control — primary reference
U.S. Government activity
79-106-7 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
900486-547 7/2 Vendor item drawing reference
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-449-3622?

NSN 5925-00-449-3622 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-449-3622?

Key specifications for 5925-00-449-3622: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-449-3622 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com