PartsTable TECHNICAL DATA SHEET
NSN 5925-00-409-3618Government record, cited

Circuit Breaker5925-00-409-3618

NSN 5925-00-409-3618 · NIIN 004093618 · Part number 1001817-22
Cae Usa Inc. · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 1PQF4
Government record, cited
NSN 5925-00-409-3618 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-409-3618. Manufacturer of record part number: 1001817-22.
Also searched as  5925-00-409-3618 · 5925004093618 · NIIN 004093618 · 00-409-3618 · FSC 5925 Circuit Breakers · CAGE 1PQF4 · 1001817-22 · AM12-5-50DC5 · 431511
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Fragility Factor: MODERATELY RUGGED
  • Body Style: SINGLE POLE TYPE
Identification
  • NSN: 5925-00-409-3618
  • NIIN: 004093618
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 1001817-22
  • Manufacturer: Cae Usa Inc.
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-409-3618, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Cae Usa Inc.. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-409-3618
Primary Part Number1001817-22
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerCae Usa Inc.
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts50.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.062 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.750 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.611 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.500 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current0.150 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedDUSTPROOF AND FUNGUS PROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 THREADED STUD
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
2915-01-074-5338431-51-1 POSSIBLE MATCH
BASE FUEL FILTER
Possible match (shared part number)Parker Hannifin Corp Dba Pneutronics
5962-01-088-948443151-1 POSSIBLE MATCH
MICROCIRCUIT,DIGITAL
Possible match (shared part number)Raytheon Company Div Rmd Strategic
6220-01-445-767143151-1 POSSIBLE MATCH
PANEL,INDICATING,LIGHT TRANSMITT
Possible match (shared part number)Fleet Readiness Center East Div Department of Navy
Cross-Reference Index
Part NumberManufacturer
1001817-22 Cae Usa Inc. (USA)
Reference documents
ReferenceMeaning
AM12-5-50DC5 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
1001817-22 5/9 Secondary reference
Raytheon Technical Services Company
431511 5/9 Secondary reference
Raytheon Technical Services Company
Related Parts
2915-01-074-5338POSSIBLE MATCH
BASE FUEL FILTER
431-51-1
5962-01-088-9484POSSIBLE MATCH
MICROCIRCUIT,DIGITAL
43151-1
6220-01-445-7671POSSIBLE MATCH
PANEL,INDICATING,LIGHT TRANSMITT
43151-1

Frequently Asked Questions

What is NSN 5925-00-409-3618?

NSN 5925-00-409-3618 is a Circuit Breaker, manufactured by Cae Usa Inc., classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-409-3618?

NSN 5925-00-409-3618 has 1 manufacturer part number on file: 1001817-22 (Cae Usa Inc.).

What NSN replaces 5925-00-409-3618?

3 possible matches (shared part number, not a government interchangeability claim): 2915-01-074-5338, 5962-01-088-9484, 6220-01-445-7671. Verify interchangeability with system specifications before substitution.

What are the specifications of 1001817-22?

Key specifications for 1001817-22: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-409-3618 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com