PartsTable TECHNICAL DATA SHEET
NSN 5925-00-409-3610Government record, cited

Circuit Breaker5925-00-409-3610

NSN 5925-00-409-3610 · NIIN 004093610 · Part number 92-3404
Eltek Energy Llc · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 31751
Government record, cited
NSN 5925-00-409-3610 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-409-3610. Manufacturer of record part number: 92-3404.
Also searched as  5925-00-409-3610 · 5925004093610 · NIIN 004093610 · 00-409-3610 · FSC 5925 Circuit Breakers · CAGE 31751 · 92-3404 · 31512 · AM12-20-50DC4
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Fragility Factor: MODERATELY RUGGED
  • Body Style: SINGLE POLE TYPE
Identification
  • NSN: 5925-00-409-3610
  • NIIN: 004093610
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 92-3404
  • Manufacturer: Eltek Energy Llc
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-409-3610, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Eltek Energy Llc. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 7 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-409-3610
Primary Part Number92-3404
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerEltek Energy Llc
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts50.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.062 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.750 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.611 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.500 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT AND 6.500 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedDUSTPROOF AND FUNGUS PROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 THREADED STUD
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 7
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5940-01-195-160431512 POSSIBLE MATCH
TERMINAL,STUD
Possible match (shared part number)Eaton Aerospace Llc Dba Eaton Aerospace Jackson
5905-01-248-9506315112 POSSIBLE MATCH
RESISTOR NETWORK,FIXED-VARIABLE
Possible match (shared part number)Vishay Intertechnology, Inc.
4810-01-260-9163M-3V 1.25 POSSIBLE MATCH
VALVE,SOLENOID
Possible match (shared part number)Gould J D Co Inc
5330-01-274-312931512 POSSIBLE MATCH
GASKET
Possible match (shared part number)Walker Mfg Co
4730-01-442-609831512 POSSIBLE MATCH
FLANGE,PIPE
Possible match (shared part number)Industrial Technologies and Services Llc
5940-01-470-6837F104270 POSSIBLE MATCH
TERMINAL,QUICK DISCONNECT
Possible match (shared part number)Tld Wollard Llc
3030-01-482-409031512 POSSIBLE MATCH
BELTING,ROUND
Possible match (shared part number)Gravograph-New Hermes, Inc
Cross-Reference Index
Part NumberManufacturer
92-3404 Eltek Energy Llc (USA)
Reference documents
ReferenceMeaning
31512 5/9 Secondary reference
Raytheon Technical Services Company
AM12-20-50DC4 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
Related Parts
5940-01-195-1604POSSIBLE MATCH
TERMINAL,STUD
31512
5905-01-248-9506POSSIBLE MATCH
RESISTOR NETWORK,FIXED-VARIABLE
315112
4810-01-260-9163POSSIBLE MATCH
VALVE,SOLENOID
M-3V 1.25
5330-01-274-3129POSSIBLE MATCH
GASKET
31512
4730-01-442-6098POSSIBLE MATCH
FLANGE,PIPE
31512
5940-01-470-6837POSSIBLE MATCH
TERMINAL,QUICK DISCONNECT
F104270
3030-01-482-4090POSSIBLE MATCH
BELTING,ROUND
31512

Frequently Asked Questions

What is NSN 5925-00-409-3610?

NSN 5925-00-409-3610 is a Circuit Breaker, manufactured by Eltek Energy Llc, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-409-3610?

NSN 5925-00-409-3610 has 1 manufacturer part number on file: 92-3404 (Eltek Energy Llc).

What NSN replaces 5925-00-409-3610?

7 possible matches (shared part number, not a government interchangeability claim): 5940-01-195-1604, 5905-01-248-9506, 4810-01-260-9163. Verify interchangeability with system specifications before substitution.

What are the specifications of 92-3404?

Key specifications for 92-3404: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-409-3610 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com